Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
[Transcatheter aortic valve implantation and conduction disturbances]
M Ait Said1, C Coquard1, J Horvilleur1
1ICPS Jacques Cartier, groupe Ramsay Générale de Santé, 6, avenue du Noyer Lambert, 91300 Massy, France.
Abstract:
Transcatheter aortic valve implantation (TAVI) is currently becoming the treatment of choice for patients with calcific aortic stenosis. Despite several technical improvements, the incidence of conduction disturbances has not diminished and remains TAVI's major complication. These disturbances include the occurrence of left bundle branch block and/or high-grade atrioventricular block often requiring pacemaker implantation. The proximity of the aortic valve to the conduction system (conduction pathways) accounts for the occurrence of these complications. Several factors have been identified as carrying a high risk of conduction disturbances like the presence of pre-existing right bundle branch block, the type of valve implanted, the volume of aortic and mitral calcifications, the size of the annulus and the depth of valve implantation. Left bundle branch block is the most frequent post TAVI conduction disturbance. Whereas the therapeutic strategy for persistent complete atrioventricular block is simple, it becomes complex in the presence of fluctuating changes in PR interval and left bundle branch block duration. The QRS width threshold value (150-160 ms) indicative of the need for pacemaker implantation is still being debated. Although there are currently no recommendations regarding the management of these conduction disturbances, the extension of TAVI indications to patient at low surgical risk calls for a standardization of our practice. However, a decision algorithm was recently proposed by a group of experts composed of interventional cardiologists, electrophysiologists and cardiac surgeons. There are still uncertainties about the appropriate timing of pacemaker implantation and the management of new onset left bundle branch block.
More Related Videos
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Catheterization III: Left Heart Catheterization
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction