Related Experiment Video
Updated: Jan 4, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Tolerability and efficacy of the concentration of iodine solution during esophageal chromoendoscopy: a double-blind
Tatsuhiro Gotoda1, Hiromitsu Kanzaki1, Yuki Okamoto1
1Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
Background And Aims:
Esophageal chromoendoscopy with iodine solution is an important diagnostic method for the detection of superficial esophageal cancer. However, the concentration of iodine solution has differed among reports. This study aimed to evaluate patient discomfort with different iodine concentrations.
Methods:
We performed a prospective, double-blind, randomized study. We prospectively enrolled and analyzed 77 patients who were at high risk for esophageal carcinoma and scheduled to undergo EGD from March 2018 to January 2019. All patients were divided into 2 groups before the procedure to compare pain measurements: a 1% iodine solution group (group A) and a 2% iodine solution group (group B). The primary endpoint of this study was the difference in pain measurement between 1% and 2% iodine solution chromoendoscopy. Secondary endpoints were safety, detection yield, and color evaluation based on both the endoscopist's survey and color values, as determined using the Commission Internationale de l'Eclairage (CIELAB, Vienna, Austria) color evaluation system, in the iodine-faded and iodine-stained area of each group.
Results:
Heartburn and retrosternal pain in group A were significantly lower than those in group B (P = .02). Eleven patients reported heartburn and retrosternal pain (group A, 2; group B, 9). Four patients reported pain above the sternal angle and 7 below the sternal angle. There was no significant difference between the 2 groups with regard to detection yield, color evaluation by the endoscopist's assessment, or color values. No patients had any adverse events, and all safely completed this study.
Conclusions:
The 2% iodine solution resulted in significantly greater pain than the 1% iodine solution, and the color of the stained esophageal images of each group was the same from this study. Therefore, the 1% iodine solution is recommended for esophageal chromoendoscopy. (Clinical trial registration number: UMIN 000029796.).
More Related Videos
10:13Eye Irritation Test EIT for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial RhCE Tissue Model
Published on: August 23, 2015
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Procedures III: Video Capsule Endoscopy
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...