Related Experiment Video
Updated: Jan 4, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Birmingham mid-head resection periprosthetic fractures: Case report
Inés Fraile Gamarra1, Juan Fernando Jiménez Viseu Pinheiro1, Carlos Cano Gala1
1Complejo Asistencial Universitario de Salamanca, Paseo de San Vicente 58-182, 37001, Spain.
This case study details a rare subtrochanteric fracture in an 81-year-old patient with a Birmingham Mid-Head Resection (BMHR) hip prosthesis. Surgical treatment involved open reduction and internal fixation, highlighting a unique fracture pattern and its management.
Area of Science:
- Orthopedic surgery
- Biomaterials science
- Geriatric medicine
Background:
- Total hip arthroplasty in young patients presents challenges in implant selection.
- The Birmingham Mid-Head Resection (BMHR) prosthesis aims to preserve bone stock.
- Femoral neck fractures are a known complication of hip resurfacing, often necessitating revision surgery.
Purpose of the Study:
- To describe a rare complication associated with the BMHR prosthesis.
- To detail the surgical management of a unique periprosthetic fracture pattern.
- To review the available literature on BMHR prosthesis complications.
Main Methods:
- Presentation of an 81-year-old patient with a subtrochanteric fracture after BMHR prosthesis implantation.
- Surgical treatment via open reduction and internal fixation with a trochanteric plate and cerclages.
- Review of literature on fracture patterns in hip resurfacing.
Main Results:
- The patient sustained a subtrochanteric fracture, differing from typical femoral neck fractures seen with resurfacing.
- The fracture extended from the cervical to the subtrochanteric area.
- Successful surgical management was achieved with internal fixation.
Conclusions:
- BMHR prostheses, while preserving bone stock, can be associated with rare fracture patterns.
- The unusual fracture pattern in this case required a specific therapeutic approach.
- This case underscores the importance of considering atypical fracture presentations in periprosthetic management.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019