Multiple Physiological Signals Fusion Techniques for Improving Heartbeat Detection: A Review
Javier Tejedor1, Constantino A García2, David G Márquez3
1Department of Information Technology, Escuela Politécnica Superior, Universidad San Pablo-CEU, CEU Universities, Campus Montepríncipe, Boadilla del Monte, 28668 Madrid, Spain. javier.tejedornoguerales@ceu.es.
This review explores robust heartbeat detection using multi-modal physiological signals. Fusing signals like electrocardiogram (ECG) and blood pressure (BP) enhances accuracy, especially in challenging conditions.
Area of Science:
- Biomedical Engineering
- Signal Processing
Background:
- Robust heartbeat detection is crucial for various medical applications.
- Multi-modal physiological signals offer complementary information for improved accuracy.
Purpose of the Study:
- To review and synthesize techniques for robust heartbeat detection using fused physiological signals.
- To identify optimal signal combinations and fusion strategies.
Main Methods:
- Literature review of multi-modal signal fusion techniques for heartbeat detection.
- Analysis of preprocessing steps including filtering, normalization, and resampling.
- Examination of fusion approaches: RR interval exploitation, signal selection, voting, and advanced methods (Bayesian, HMM, neural networks).
Main Results:
- Electrocardiogram (ECG), blood pressure (BP), and artificial blood pressure (ABP) are primary signals for robust detection.
- Inclusion of stroke volume (SV), photoplethysmogram (PPG), electromyogram (EMG), electroencephalogram (EEG), and electrooculogram (EOG) can further enhance performance.
- Signal quality assessment and delay correction are critical preprocessing steps.
Conclusions:
- Multi-modal signal fusion significantly improves heartbeat detection robustness.
- Guidelines for future research and performance comparison are provided.
- Future research should focus on advanced fusion techniques and signal quality assessment.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Dysrhythmias V: Evaluating Dysrhythmias