Related Experiment Video
Updated: Jan 4, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Gross Tumor Delineation in Esophageal Cancer on MRI Compared With 18F-FDG-PET/CT
Sophie E Vollenbrock1, Marlies E Nowee2, Francine E M Voncken2
1Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
Purpose:
Current delineation of the gross tumor volume (GTV) in esophageal cancer relies on computed tomography (CT) and combination with 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET). There is increasing interest in integrating magnetic resonance imaging (MRI) in radiation treatment, which can potentially obviate CT- or FDG-PET/CT-based delineation. The aim of this study is to evaluate the feasibility of target delineation on T2-weighted (T2W) MRI and T2W including diffusion-weighted MRI (T2W + DW-MRI) compared with current-practice FDG-PET/CT.
Methods:
Ten observers delineated primary esophageal tumor GTVs of 6 patients on FDG-PET/CT, T2W-MRI, and T2W + DW-MRI. GTVs, generalized conformity indices, in-slice delineation variation (root mean square), and standard deviations in the position of the most cranial and caudal delineated slice were calculated.
Results:
Delineations on MRI showed smaller GTVs compared with FDG-PET/CT-based delineations. The main variation was seen at the cranial and caudal border. No differences were observed in conformity indices (FDG-PET/CT, 0.68; T2W-MRI, 0.66; T2W + DW-MRI, 0.68) and in-slice variation (root mean square, 0.13 cm on FDG-PET/CT; 0.10 cm on T2W-MRI; 0.14 cm on T2W + DW-MRI). In the 2 tumors involving the gastroesophageal junction, addition of DW-MRI to T2W-MRI significantly decreased caudal border variation.
Conclusions:
MRI-based target delineation of the esophageal tumor is feasible with interobserver variability comparable to that with FDG-PET/CT, despite limited experience with delineation on MRI. Most variation was seen at cranial-caudal borders, and addition of DW-MRI to T2W-MRI may reduce caudal delineation variation of gastroesophageal junction tumors.
More Related Videos
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET