Related Experiment Video
Updated: Jan 4, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Incomplete insertion of pedicle screws in a standard construct reduces the fatigue life: A biomechanical analysis
Yo-Lun Chu1, Chia-Hsien Chen2,3,4, Fon-Yih Tsuang5
1Department of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.
Abstract:
Pedicle screws are commonly used for posterior stabilization of the spine. When used in deformed or degenerated segments, the pedicle screws are often not fully inserted into the bone, but instead the threaded portion is exposed by 1 or 2 threads to accommodate rod placement and ensure alignment between the tulip of the screw and the rod. However, broken pedicle screws have been reported with the use of this method. The aim of this study was to determine how the fatigue life of the screw is affected by not fully inserting the screw into the bone. Spinal constructs were evaluated in accordance with ASTM F1717. The following three screw positions were subjected to compression bending fatigue loading; (i) pedicle screw fully inserted in the test block with no threads exposed (EXP-T0), (ii) pedicle screw inserted with one thread exposed outside the test block (EXP-T1), (iii) pedicle screw inserted with two threads exposed outside the test block (EXP-T2). Corresponding finite element models FEM-T0, FEM-T1 and FEM-T2 were also constructed and subjected to the same axial loading as the experimental groups to analyze the stress distribution in the pedicle screws and rods. The results showed that under a 190 N axial load, the EXP-T0 group survived the full 5 million cycles, the EXP-T1 group failed at 3.7 million cycles on average and the EXP-T2 groups failed at 1.0 million cycles on average, while the fatigue strength of both the EXP-T1 and EXP-T2 groups was 170 N. The constructs failed through fracture of the pedicle screw. In comparison to the FEM-T0 model, the maximum von Mises stress on the pedicle screw in the FEM-T1 and FEM-T2 models increased by 39% and 58%, respectively. In conclusion, this study demonstrated a drastic decrease in the fatigue life of pedicle screws when they are not full inserted into the plastic block.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fatigue
Residual Stresses in Circular Shafts
Screw: Problem Solving
To evaluate the...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.