Inter- and intra-observer variability in fetal ductus venosus blood flow measurements in high-risk fetuses at 26-32 weeks
Related Experiment Video
Updated: Jan 4, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Clara M Bruin1, Wessel Ganzevoort1, Ewoud Schuit2
1Department of Obstetrics and Gynaecology, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands.
Insights
The ductus venosus pulsatility index for veins (DV PIV) shows acceptable clinical use when averaging three measurements. Inter-observer variation was lower than intra-observer variation, suggesting improved reliability for fetal growth restriction monitoring.
Area of Science:
- Perinatology
- Fetal Medicine
- Diagnostic Ultrasound
Background:
- Early preterm fetal growth restriction (FGR) significantly impacts perinatal outcomes.
- The ductus venosus pulsatility index for veins (DV PIV) is a potential monitoring tool for FGR.
- Current data on DV PIV's test characteristics and reliability are limited.
Purpose of the Study:
- To evaluate the inter- and intra-observer variability of DV PIV measurements.
- To assess the robustness of DV PIV as a clinical monitoring tool for early preterm FGR.
Main Methods:
- Doppler sonographic assessments were performed on 19 women between 26-32 weeks gestation.
- Two maternal-fetal medicine specialists independently obtained three DV PIV tracings each.
- Variability and agreement were analyzed using Bland-Altman methods and intraclass correlation coefficients (ICCs).
Main Results:
- Inter-observer variation showed proportional limits of agreement from -0.29 to 0.19 (ICC = 0.89).
- Intra-observer variation yielded proportional limits of agreement ranging from -0.48 to 0.62 (ICCs = 0.66-0.68).
- Inter-observer variability was significantly lower than intra-observer variability.
Conclusions:
- DV PIV demonstrates acceptable test characteristics for clinical application.
- Averaging at least three consecutive DV PIV measurements mitigates biological variation and improves reliability.
- DV PIV is a promising tool for monitoring early preterm fetal growth restriction.
Objectives:
Early preterm fetal growth restriction is a significant contributor to perinatal morbidity and mortality. The ductus venosus pulsatility index for veins (DV PIV) is proposed as a monitoring tool because it appears to improve perinatal outcomes. The test characteristics and robustness of DV PIV have been inadequately described. The aim of this study was to investigate inter- and intra-observer variability of DV PIV.
Study Design:
Nineteen women with a gestational age between 26 and 32 completed weeks were included in this study. Doppler sonographic fetal assessment was performed by two independent maternal-fetal medicine specialists. Each sonographer alternately performed three flow tracings for each participant, in the absence of the other sonographer (six tracings in total per patient). DV PIV was calculated automatically from stored tracings by a third researcher. Inter- and intra-observer variability of DV PIV and limits of agreement were assessed using the Bland-Altman method. Comparison of the distribution was performed with Kendall's related samples test, and the intraclass correlation coefficient (ICC) was calculated.
Results:
In total, 114 DV measurements were taken from 19 participants with a median age of 31 years [interquartile range (IQR) 26-34 years] at a median gestational age of 28 weeks (IQR 27-29 weeks). The proportional limits of agreement for intra-observer variation were -0.48 to 0.48 and -0.39 to 0.62 for the two observers. ICCs were 0.66 [95% confidence interval (CI) 0.42-0.84] and 0.68 (95% CI 0.45-0.85). The proportional limits of agreement for inter-observer variation were -0.29 to 0.19 with an ICC of 0.89 (95% CI 0.73-0.96).
Conclusion:
Inter-observer variation was far less than intra-observer variation, probably due to mitigation of biological variation by averaging three measurements. DV PIV has acceptable test characteristics for use in a clinical setting when the average of at least three consecutive measurements is used.