Related Experiment Video
Updated: Jan 4, 2026

Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Reliability of Anthropometry-Based Equations Compared to Dual Energy Absorptiometry for Assessing Body Composition in
Avinash Kumar Dubey1, P S Priyamvada1, Jayaprakash Sahoo2
1Department of Nephrology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
Objectives:
Skinfold thickness measurements for assessing body composition are reported to have good reproducibility compared to the reference method of dual energy absorptiometry (DXA). In the current study, we compared the level of agreement between body composition measured with DXA and skinfold thickness (SFT) in CKD Stage 3 and 4, at 2 occasions, 6 months apart.
Methods:
Body composition was assessed in 177 Indian patients with CKD Stage 3 and 4 using DXA and anthropometry (SFT). The body fat mass obtained by the 2 methods was compared by paired t-test, intraclass correlation coefficients, regression analysis, and Bland-Altman plots. A linear regression analysis was done to identify the patient-related parameters which would account for the intermethod differences between DXA and SFT.
Results:
Compared to DXA, SFT underestimated the fat mass at baseline as well as 6 months [DXA vs. SFT at entry: 15.85 kg (95% confidence interval, CI 15.07-16.65) vs. 13.71 kg (95% CI 13.21-14.32), P < .001; at 6 months: 16.13 (95% CI 15.33-16.93) vs. 13.85 (95% CI 13.25-14.45), P < .001]. The intraclass correlation coefficients at entry and 6 months were 0.894 (0.857-0.921) and 0.896 (0.860-0.923), respectively. The intermethod differences between DXA and SFT at baseline and 6 months were comparable: 2.08 kg (95% CI 1.66-2.5) at baseline versus 2.27 kg (95% CI 1.83-2.71) at 6 months, P = 0.200. Gender and body mass index turned out to be the significant predictors of intermethod differences at base line and exit (P < .001).
Conclusions:
SFT-based measurements show good reproducibility compared to DXA over a period of 6 months. However, SFT systematically underestimates the fat mass by 2 Kg compared to DXA.
More Related Videos
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Chronic Kidney Disease III: Interprofessional Care
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Chronic Kidney Disease II: Clinical Manifestations

