Related Experiment Video
Updated: Jan 4, 2026

Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
GlideScope® versus Macintosh laryngoscope for assessment of post-thyroidectomy vocal cord dysfunction: prospective
Marwa A Elbeialy1, Ahmed M Maarouf2, Amin M Alansary3
1Department of Anesthesiology, Intensive Care and Pain Management, Faculty of Medicine, Ain Shams University, Cairo, Egypt - mar_khairy@yahoo.com.
Background:
Early detection of post-thyroidectomy vocal cord dysfunction is crucial. This study compared GlideScope® with Macintosh direct laryngoscope (MDL) regarding the accuracy of assessment of post-thyroidectomy vocal cord dysfunction.
Methods:
One hundred and twenty patients scheduled for elective thyroidectomy, aged 18 - 50 years, of either sex were enrolled in the study. Standard general anesthesia technique was used in all patients. At the end of operation, patients were randomly allocated into one of the following sequences: 1) examined with MDL then GlideScope®, or 2) examined with GlideScope® then MDL. Postoperative tele-laryngoscopic examination was done after 12 hours. The primary outcome of the study was the sensitivity and the specificity of GlideScope® to detect vocal cord dysfunction while the secondary outcomes were the Cormack-Lehane grade of the glottis visualization and the incidence of complications.
Results:
The incidence of vocal cord dysfunction was 15 (12.5%); all cases were unilateral. The GlideScope® was more sensitive (86.7%) and specific (95.2%) with higher diagnostic accuracy (94.2%) for detecting vocal cord dysfunction than MDL. There was a high agreement between the GlideScope® findings and the final diagnosis (kappa 0.754 [95% CI: 0.581-0.928]). Cormack-Lehane score was significantly better by the GlideScope® than by the MDL (P<0.001). The incidence of hoarseness of voice was 32 (26.7%) with eight cases among the diagnosed patients. No cases of aspiration or stridor were recorded.
Conclusions:
This study demonstrates that GlideScope® is a better alternative to MDL for an accurate detection of post-thyroidectomy vocal cord dysfunction.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Larynx
Anatomy of the Larynx
The larynx consists of various components, including cartilage, muscles, and vocal cords. Its structure includes three large unpaired cartilages—the thyroid, cricoid, and epiglottis—and three smaller paired cartilages—the arytenoids,...
Tracheostomy Suctioning II: Procedure
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:

