Related Experiment Video
Updated: Jan 4, 2026

Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Rapid selection of analytical lines for SAF-LIBS based on the doublet intensity ratios at the initial and final
Abstract:
Self-absorption-free laser-induced breakdown spectroscopy (SAF-LIBS) can directly obtain the applicable quasi-optically thin lines by determining the optimal acquisition delay time according to the intensity ratio of doublet lines at specific transition wavelength of the analyzed elements, thus eliminating the influence of self-absorption on quantitative results. In quantitative analysis of samples with a certain content range, the key to the convenient application of this technique is to rapidly select the suitable doublet lines for the element to be analyzed. The theoretical analysis shows that the evolution trend of doublet intensity ratio is monotonous under the assumptions that the plasma is uniform and in local thermal equilibrium (LTE) and the area density (Nl) is a constant, which is also confirmed by the experimental results of Cu and Al. Thus, a rapid spectral line selection criterion for SAF-LIBS applications is derived: only when the doublet intensity ratios measured at the initial and final stages of plasma induced by the boundary sample with the highest element content lie on both sides of the theoretical ratio, the doublet lines can reach quasi-optically thin during plasma evolution and are suitable for SAF-LIBS measurements. This new criterion is helpful to promote the practicality and industrial application of SAF-LIBS technology.
More Related Videos
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview