Related Experiment Video
Updated: Jan 4, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Numerical Elucidation of Flow and Dispersion in Ordered Packed Beds: Nonspherical Polygons and the Effect of Particle
Fabian Dolamore, Simone Dimartino1, Conan J Fee
1Institute for Bioengineering, School of Engineering , The University of Edinburgh , Edinburgh EH9 3FB , U.K.
Abstract:
Spherical particles are widely considered as the benchmark stationary phase for preparative and analytical chromatography. Although this has proven true for randomly packed beds in the past, we challenge this paradigm for ordered packings, the fabrication of which are now feasible through additive manufacturing (3D printing). Using computational fluid dynamics (Lattice Boltzmann Method) this work shows that nonspherical particles can both reduce mobile-phase band broadening and increase permeability compared with spheres in ordered packed beds. In practice, ordered packed beds can only remain physically stable if the particles are fused to form a contiguous matrix, thus creating a positional overlap at the points of fusion between what would otherwise be discrete particles. Overlap is shown to decrease performance of ordered packed beds in all observed cases, thus we recommend it should be kept to the minimum extent necessary to ensure physical stability. Finally, we introduce a metric to estimate column performance, the mean deviated velocity, a quantitative description of the spread of the velocity field in the column. This metric appears to be a good indicator of mobile-phase dispersion in ordered packed bed media, including overlapped beds, and is a useful tool for screening new stationary-phase morphologies without having to perform computationally expensive simulations.
Related Concept Videos
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Analyte Adsorption and Distribution

