Related Experiment Video
Updated: Jan 4, 2026

Transforaminal Full-Endoscopic Lumbar Foraminotomy Under Local Anesthesia for L5/S1 Adjacent Segment Foraminal Stenosis
Published on: October 17, 2025
Quantitative evaluation for cervical foraminal bony stenosis based on angled sagittal slices along a nerve root on
Mitsunori Ozaki1, Kazuya Nishioka2, Mari Kitayama1
1Department of Neurological Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama 641-0012, Japan.
Abstract:
Cervical foraminal canal stenosis is a common disease, but any relationships between the measurement values of cervical foraminal canals and clinical symptoms have yet to be explored. We aim to determine a numerical cutoff point of cervical foraminal bony canal size that does not lead to radiculopathy so as to establish criteria for the surgical indication. We reconstructed angled sagittal slices along a nerve root on computed tomography (CT) on a workstation from pre-operative CT data and measured 1152 cervical foraminal canals (144 patients) from Cervical (C) 4/5 to C7/Thoracic (Th) 1. We evaluated the relationship between the size of foraminal canals and clinical manifestations. Receiver operating characteristic (ROC) analysis was used to calculate cutoff points of each foraminal canal size with positive neurologic manifestations. Of the 144 patients' 1152 nerve roots, 286 nerve roots (24.8%) were diagnosed as radiculopathy by neurological examinations. The mean measured value of all foraminal canals on angled sagittal CT imagery was 3.39 ± 1.37 mm. The cutoff point of foraminal canal sizes without radiculopathy was 2.7 mm (sensitivity 0.680, specificity 0.591) overall. A cutoff point ascertained by quantitative evaluation of cervical foraminal canal size is useful for making diagnosis of cervical foraminal canal bony stenosis.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...