Related Experiment Video
Updated: Jan 4, 2026

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Investigator-initiated, multicentre, open-label, two-arm, randomised controlled trial comparing intubating conditions
Anne-Sophie Falempin1, Bruno Pereira2, Fatima Binakdane3
1Department of Perioperative Medicine, University Hospital-Clermont-Ferrand, Clermont-Ferrand Cedex 1, France.
Introduction:
Difficult airway management during tracheal intubation can lead to severe hypoxic sequelae. Routine intubation practice is to use a strict supine position, whereas a 25° head-up or reverse Trendelenburg position increases efficacy of preoxygenation, seems more comfortable for the anaesthetist and may also provide better intubation conditions in direct laryngoscopy. The 25° head-up position could be used for the whole population rather than only for obese patients, but there is no prospective randomised controlled trial with a robust design and large number of patients comparing strict supine against 25° intubation in operating room. The objective of the InSize25 study is to test the effect of these two patient positions on intubation conditions during laryngoscopy in scheduled surgery on non-obese patients.
Methods And Analysis:
InSize25 is an investigator-initiated, multicentre, open-label, two-arm, randomised controlled trial. The InSize25 study will randomise 1000 adult patients scheduled for surgery under general anaesthesia requiring intubation with neuromuscular-blocking drugs, candidates for direct laryngoscopy. The primary outcome variable is the view obtained during the first laryngoscopy without any external manipulation assessed using percentage of glottic opening. Important secondary outcomes are: Cormack-Lehane classification, number of attempts at laryngoscopy and at tracheal intubation, use of ancillary equipment (eg, bougies, alternative laryngoscope blades, videolaryngoscope) and manoeuvres (eg, laryngeal manipulation), comfort score for the anaesthetist, episodes of postinduction hypotension or desaturation and mechanical complications of intubation.
Ethics And Dissemination:
The trial received appropriate approval from the 'CPP Sud-Est II' ethical review board. Informed consent is required. If the 25° head-up position proves superior for tracheal intubation without more complications, it may become the routine-standard intubation position rather than only for use with obese patients. The final results will be published in a peer-reviewed journal.
Trial Registration Number:
Clinicaltrials.gov identifier (NCT03339141).
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

