Analysis of the Regulatory Divergence of Comparative Dissolution Requirements for Post-Approval Manufacturing Changes

Connie Langer1, Dorys Argelia Diaz2, Leslie Van Alstine3

  • 1Global Product Development, Global Chemistry, Manufacturing & Controls, Pfizer Inc., Eastern Point Road, Groton, Connecticut, 06340, USA. connie.s.langer@pfizer.com.

The AAPS Journal
|November 6, 2019
PubMed

Related Concept Videos

Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
199
FDA Approved Drugs: Changes to Approved Drugs01:26

FDA Approved Drugs: Changes to Approved Drugs

Post-approval, manufacturers may modify an approved new or generic drug product. Such modifications can encompass alterations in the Active Pharmaceutical Ingredient (API), manufacturing process, formulation, batch size, manufacturing site, and container closure system (FDA Guidance for Industry, April 2004). Often, a drug product may undergo multiple changes.These modifications require careful evaluation to determine their potential impact on the drug product's identity, strength, quality,...
188
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence01:27

Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence

Changes in polymorphic forms can significantly influence the bioavailability of poorly soluble drugs. Although the FDA defines pharmaceutical equivalence based on having the same active ingredient, dosage form, and route of administration, it does not automatically disqualify products with different polymorphic forms. This means two products with different polymorphs can still be deemed pharmaceutically equivalent. However, polymorphic differences can affect properties like wettability,...
125
Bioequivalence studies: Biowaivers01:13

Bioequivalence studies: Biowaivers

Body:In certain scenarios, in vitro dissolution tests can replace in vivo bioequivalence studies. This is particularly true when a drug product, though available in varying strengths, maintains proportional similarity in its active and inactive ingredients. In such cases, the need for in vivo bioequivalence studies for lower strength variants may be waived, provided dissolution tests and in vivo studies on the highest strength yield satisfactory results.Bioequivalence can be indicated through...
188
Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...
167
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
249