Published on: December 8, 2011
A Novel Approach to Quantifying Lymphatic Contractility during Indocyanine Green Lymphangiography
Melisa D Granoff1, Anna Rose Johnson1, Bernard T Lee1
1From the Department of Surgery, Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School; and the Department of Radiation Oncology, Edwin L. Steele Laboratory, Massachusetts General Hospital.
Abstract:
Lymphedema arises from impaired lymphatic function. Quantification of lymphatic contractility has previously been shown using a custom-built near-infrared imaging system. However, to broaden the clinical use of functional lymphatic measurements, these measurements need to be performed using a standard-of-care, clinically available camera. The authors propose an objective, algorithmic, and clinically accessible approach to quantify lymphatic contractility using a 3-minute indocyanine green lymphangiograph recorded with a commercially available near-infrared camera. A retrospective review of the authors' indocyanine green lymphangiography video repository maintained in a Research Electronic Data Capture database was performed. All patients with a newly diagnosed unilateral breast cancer undergoing preoperative indocyanine green lymphangiography were included in the analysis. Patient medical records were then analyzed for patient demographics, and videos were analyzed for contractility. Seventeen consecutive patients with unilateral breast cancers underwent video processing to quantify lymphatic contractility of the ipsilateral extremity in contractions per minute. All patients were women, with an average age of 60.5 years (range, 38 to 84 years). The average lymphatic contractility rate was 1.13 contractions per minute (range, 0.67 to 2.5 contractions per minute). Using a clinically accessible standard-of-care device for indocyanine green lymphangiography, the authors were able to determine lymphatic contractility rates of a normal extremity. The authors' finding falls within the range of previously published data quantifying lymphatic contractility using a research device, suggesting that the authors' technique provides a clinically accessible, time-effective means of assessing lymphatic contractility. Potential future applications include both lymphedema surveillance and evaluation of nonsurgical and surgical interventions. CLINICAL QUESTION/LEVEL OF EVIDENCE:: Diagnostic, IV.