Related Experiment Video
Updated: Jan 4, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
A New and Unexpected Complication After Arch Stent Grafting for Residual Dissection
Augusto D'Onofrio1, Giorgia Cibin1, Raphael Caraffa1
1Division of Cardiac Surgery, University of Padova, Padova, Italy.
Abstract:
This report describes a complication after stent grafting of the aortic arch for residual dissection after ascending aorta and aortic arch replacement for acute type A dissection. One year later, a pseudoaneurysm originating from the proximal suture line and therefore far from the stent graft landing zone developed and fistulized into the pulmonary artery. Possible causes were suture damage during stent deployment and change of system forces after stent placement leading to high tension on the suture line. Emergency surgery was performed. Aortic arch stent grafting is a new and promising technique, but its complications are still not completely known.
Related Concept Videos
Aneurysm III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management