Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model

Kai Scherer1,2, Johannes Hammel3,4, Thorsten Sellerer4

  • 1Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany. kai.scherer@tum.de.

Scientific Reports
|November 7, 2019
PubMed

Insights

Dual-energy CT enhances myocardial perfusion imaging for assessing heart disease. This study demonstrates quantitative iodine-based analysis in a porcine model, improving accuracy and potentially reducing radiation and contrast agent doses.

Area of Science:

  • Cardiovascular imaging
  • Radiology
  • Medical physics

Background:

  • Ischemic heart disease is a leading global cause of mortality.
  • Conventional CT angiography has limitations in assessing myocardial functional hemodynamics.
  • Dual-energy CT offers advanced solutions for overcoming these limitations.

Purpose of the Study:

  • To perform a quantitative, iodine-based analysis of myocardial dynamics using dual-layer spectral CT.
  • To evaluate the potential for dose and contrast agent reduction in myocardial CT perfusion imaging.
  • To establish a sensitive tool for assessing and monitoring early myocardial ischemia.

Main Methods:

  • Utilized dual-layer spectral CT for myocardial perfusion imaging in a porcine model.
  • Employed quantitative measurements of peak enhancement, perfusion, time to peak, and iodine volume.
  • Implemented a two-shot acquisition approach to assess dose and contrast reduction.

Main Results:

  • Achieved quantitative measurements of myocardial dynamics: peak enhancement (0.92 mg/ml), perfusion (0.085 mg/ml/s), time to peak (17.12 s), and iodine volume (29.89 mg/ml*s).
  • Demonstrated the feasibility of reducing radiation dose to 18 mGy and contrast volume to 30 mL.
  • Measured in-vivo myocardial iodine concentrations as low as 1 mg/ml.

Conclusions:

  • Dual-layer spectral CT enables robust, quantitative iodine-based myocardial perfusion imaging.
  • This technique shows significant potential for reducing radiation dose and contrast agent volume.
  • Dynamic quantitative iodine perfusion imaging is a promising tool for early myocardial ischemia detection and management.