Related Experiment Video
Updated: Jan 4, 2026

Impact Assessment of Repeated Exposure of Organotypic 3D Bronchial and Nasal Tissue Culture Models to Whole Cigarette Smoke
Published on: February 12, 2015
The impact of unmeasured within- and between-cluster confounding on the bias of effect estimatorsof a continuous
Yun Li1,2,3, Yoonseok Lee4, Friedrich K Port3
1Department of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, Philadelphia, PA, USA.
Abstract:
Unmeasured confounding almost always exists in observational studies and can bias estimates of exposure effects. Instrumental variable methods are popular choices in combating unmeasured confounding to obtain less biased effect estimates. However, we demonstrate that alternative methods may give less biased estimates depending on the nature of unmeasured confounding. Treatment preferences of clusters (e.g. physician practices) are the most frequently used instruments in instrumental variable analyses. These preference-based instrumental variable analyses are usually conducted on data clustered by region, hospital/facility, or physician, where unmeasured confounding often occurs within or between clusters. We aim to quantify the impact of unmeasured confounding on the bias of effect estimators in instrumental variable analysis, as well as several common alternative methods including ordinary least squares regression, linear mixed models, and fixed-effect models to study the effect of a continuous exposure (e.g. treatment dose) on a continuous outcome. We derive closed-form expressions of asymptotic bias of estimators from these four methods in the presence of unmeasured within- and/or between-cluster confounders. Simulations demonstrate that the asymptotic bias formulae well approximate bias in finite samples for all methods. The bias formulae show that instrumental variable analyses can provide consistent estimates when unmeasured within-cluster confounding exists, but not when between-cluster confounding exists. On the other hand, fixed-effect models and linear mixed models can provide consistent estimates when unmeasured between-cluster confounding exits, but not for within-cluster confounding. Whether instrumental variable analyses are advantageous in reducing bias over fixed-effect models and linear mixed models depends on the extent of unmeasured within-cluster confounding relative to between-cluster confounding. Furthermore, the impact of unmeasured between-cluster confounding on instrumental variable analysis estimates is larger than the impact of unmeasured within-cluster confounding on fixed-effect model and linear mixed model estimates. We illustrate the use of these methods in estimating the effect of erythropoiesis stimulating agents on hemoglobin levels. Our findings provide guidance for choosing appropriate methods to combat the dominant types of unmeasured confounders and help interpret statistical results in the context of unmeasured confounding.
More Related Videos
06:55Inverse Probability of Treatment Weighting Propensity Score using the Military Health System Data Repository and National Death Index
Published on: January 8, 2020
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
Strategies for Assessing and Addressing Confounding
Confounding can be addressed at both the design phase of a study and through analytical methods after data...
Confounding in Epidemiological Studies
Bias in Epidemiological Studies
Bias
In statistics, a sampling bias is created when a sample is collected from a population, and some members of the population are not as likely to be chosen as others (remember, each member...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Uncertainty in Measurement: Accuracy and Precision