Related Experiment Video
Updated: Jan 4, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Extensive aortic surgery in acute aortic dissection type A on outcome - insights from 25 years single center
Bashar Dib1, Philipp Christian Seppelt2, Rawa Arif1
1Department of Cardiac Surgery, University Hospital Heidelberg, Heidelberg, Germany.
Background:
This single center study compares the different surgical techniques used in the treatment of acute aortic dissection type A (AADA) analyzing the influence of the extent of the surgical approach on outcome.
Methods:
From 1988 to 2012, 407 patients were operated for AADA. The cohort was divided into subgroups according to the surgical approach. These groups were compared with the supracommissural replacement group (SCR; n = 141). Groups included aortic valve sparing techniques (AVS; n = 29), Composite replacement (COMP; n = 119), COMP with total arch replacement (COMP+TAR; n = 27) and SCR with TAR (n = 75).
Results:
Compared to SCR alone, operation (p = 0.005), bypass-, cross-clamp and circulatory arrest times were longer in SCR + TAR (all p < 0.001). Moreover, operation, bypass and cross clamp times were longer in COMP+TAR (p = 0.003, p = 0.002 and p < 0.001 respectively). COMP alone and AVS required longer cross-clamp time, too (p < 0,001 and p = 0.002, respectively). Overall 30-day mortality was 21% with the observed lowest rate after AVS (14%, SCR 18%, COMP 25%) but differences in 30-day mortality were not statistically significant. The estimated 10-year survival was 42%, especially AVS demonstrated a good 10-year survival (69%). David technique was superior to Yacoub technique concerning incidence of redo interventions (p = 0.036). Risk factors for early mortality included age, circulatory arrest, general malperfusion, bypass and operation time. Circulatory arrest per se was revealed as risk factor for long-term survival.
Conclusions:
Within our single center retrospective study concomitant aortic root repair or aortic arch replacement for AADA demonstrated acceptable early and long-term survival. Circulatory arrest, long bypass and operation times per se might be important risk factors for early mortality. AVS techniques can be performed safely and have good outcomes in acute aortic dissection repair.