Related Experiment Video
Updated: Jan 4, 2026

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Effect of sampling frequency on fractal fluctuations during treadmill walking
Vivien Marmelat1, Austin Duncan1, Shane Meltz1
1Department of Biomechanics, University of Nebraska at Omaha, Omaha, Nebraska, United States of America.
Abstract:
The temporal dynamics of stride-to-stride fluctuations in steady-state walking reveal important information about locomotor control and can be quantified using so-called fractal analyses, notably the detrended fluctuation analysis (DFA). Gait dynamics are often collected during treadmill walking using 3-D motion capture to identify gait events from kinematic data. The sampling frequency of motion capture systems may impact the precision of event detection and consequently impact the quantification of stride-to-stride variability. This study aimed i) to determine if collecting multiple walking trials with different sampling frequency affects DFA values of spatiotemporal parameters during treadmill walking, and ii) to determine the reliability of DFA values across downsampled conditions. Seventeen healthy young adults walked on a treadmill while their gait dynamics was captured using different sampling frequency (60, 120 and 240 Hz) in each condition. We also compared data from the highest sampling frequency to downsampled versions of itself. We applied DFA to the following time series: step length, time and speed, and stride length, time and speed. Reliability between experimental conditions and between downsampled conditions were measured with 1) intraclass correlation estimates and their 95% confident intervals, calculated based on a single-measurement, absolute-agreement, two-way mixed-effects model (ICC 3,1), and 2) Bland-Altman bias and limits of agreement. Both analyses revealed a poor reliability of DFA results between conditions using different sampling frequencies, but a relatively good reliability between original and downsampled spatiotemporal variables. Collectively, our results suggest that using sampling frequencies of 120 Hz or 240 Hz provide similar results, but that using 60 Hz may alter DFA values. We recommend that gait kinematics should be collected at around 120 Hz, which provides a compromise between event detection accuracy and processing time.
Related Concept Videos
Sampling Theorem
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Upsampling
Discrete Fourier Transform
Construction of Frequency Distribution
First, make a table with two columns—one with the title of the data that needs to be organized, and the other column for frequency. [Draw a third column for tally marks if needed]. Then, take a look at the items given in the data set and decide if an ungrouped frequency distribution table or a grouped frequency distribution table would be more suitable. If there are large sets of different values, then it is...

