Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Steady Flow of a Fluid Stream01:27

Steady Flow of a Fluid Stream

629
Consider a control volume, such as a pipe with solid boundaries, through which fluid flows and changes direction due to the impulse exerted by the resulting force from the pipe walls. In steady flow, the mass of fluid entering the control volume at a given time, t, with velocity v1, is equal to the mass leaving after infinitesimal time dt, with velocity v2.
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
629
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

777
A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
777
Gradually Varying Flow01:29

Gradually Varying Flow

365
Gradually varying flow (GVF) in open channels describes situations where water depth changes slowly along the channel due to factors like non-uniform bed slope, channel shape variations, or obstructions. This flow type occurs when the depth adjusts gradually to balance gravitational forces, shear forces, and energy requirements, resulting in a low rate of depth change.Characteristics of Gradually Varying FlowGVF is commonly observed in natural streams, rivers, and canals, where flow depth...
365
Urodynamic Studies: Uroflowmetry01:19

Urodynamic Studies: Uroflowmetry

2.8K
Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...
2.8K
Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

1.1K
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
1.1K
General External Flow Characteristics01:26

General External Flow Characteristics

488
The study of external flow is essential for creating structures and objects that interact efficiently and safely with moving fluids, such as air or water. When a body is immersed in a flowing fluid, it experiences two primary forces: drag, which opposes motion along the flow direction, and lift, which acts perpendicular to the flow. The shape, size, and orientation of the object influence these forces.Streamlined and Blunt Bodies in External FlowObjects in fluid flow are classified as...
488

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

In-depth look at the use of pixel variance and the noise power spectrum in digital mammography quality control.

Journal of medical imaging (Bellingham, Wash.)·2025
Same author

De-implementation of inappropriate inhaled corticosteroid use in patients with COPD in general practice, results of a mixed methods study.

NPJ primary care respiratory medicine·2025
Same author

The sustainability of practice-based research networks across the globe - insights from a worldwide qualitative study.

BMC health services research·2025
Same author

Emotional Supportive Care Needs in Patients with Advanced Cancer and Their Associated Characteristics: A Multicenter Observational Cohort Study (eQuiPe Study).

Journal of palliative medicine·2025
Same author

Gout diagnoses uncertain when made by general practitioners without serum uric acid testing: an observational study.

Clinical rheumatology·2024
Same author

The impact of early breaking bad news education: a qualitative study into students' self-reported take-home messages.

MedEdPublish (2016)·2023

Related Experiment Video

Updated: Jan 4, 2026

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
09:58

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp

Published on: February 3, 2014

8.8K

Feedback information from flow volume curves to the practice.

Tjard Schermer1, Joliet Hartman2, Chantal Lauwers1

  • 1Department of General Practice, University of Nijmegen, The Netherlands.

Primary Care Respiratory Journal : Journal of the General Practice Airways Group
|November 9, 2019
PubMed
Summary

Viewing flow volume (F/V) curves during spirometry improved test quality for practice assistants. This modest improvement in spirometry test quality suggests F/V curve feedback is beneficial in general practice settings.

More Related Videos

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

9.8K
Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
11:00

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section

Published on: July 19, 2016

11.9K

Related Experiment Videos

Last Updated: Jan 4, 2026

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
09:58

Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp

Published on: February 3, 2014

8.8K
Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

9.8K
Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
11:00

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section

Published on: July 19, 2016

11.9K

Area of Science:

  • Pulmonary Function Testing
  • Spirometry Quality Improvement
  • General Practice Diagnostics

Background:

  • Spirometry is crucial for diagnosing respiratory conditions.
  • Test quality can be variable, especially when performed by non-specialists.
  • Flow volume (F/V) curves offer real-time feedback during spirometry.

Purpose of the Study:

  • To determine if real-time F/V curve visualization enhances spirometry quality.
  • To assess the impact of F/V curve feedback on key spirometry metrics.
  • To evaluate the utility of F/V curve feedback for practice assistants.

Main Methods:

  • Randomized controlled crossover study with 47 healthy subjects.
  • Practice assistants performed spirometry under 'unblinded' (F/V curves visible) and 'blinded' conditions.
  • Key outcomes included FEV1, FVC, PEF, and repeatability; technician preference was also recorded.

Main Results:

  • Higher Peak Expiratory Flow (PEF) values were observed in the unblinded condition (0.43 L/s).
  • No significant differences were found in FEV1, FVC, or repeatability.
  • One technician favored unblinded F/V curves in 62% of tests (p=0.012).

Conclusions:

  • Real-time F/V curve feedback offers a modest improvement in spirometry test quality.
  • This feedback mechanism is recommended for use by practice assistants in general practice.