Validity of simplified, calibration-less exercise intensity measurement using resting heart rate during sleep: a
Hirotaka Matsuura1, Masahiko Mukaino1, Yohei Otaka1
11Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Japan.
Background:
The recent development of wearable devices has enabled easy and continuous measurement of heart rate (HR). Exercise intensity can be calculated from HR with indices such as percent HR reserve (%HRR); however, this requires an accurate measurement of resting HR, which can be time-consuming. The use of HR during sleep may be a substitute that considers the calibration-less measurement of %HRR. This study examined the validity of %HRR on resting HR during sleep in comparison to percent oxygen consumption reserve (%VO2R) as a gold standard. Additionally, a 24/7%HRR measurement using this method is demonstrated.
Methods:
Twelve healthy adults aged 29 ± 5 years underwent treadmill testing using the Bruce protocol and a 6-min walk test (6MWT). The %VO2R during each test was calculated according to a standard protocol. The %HRR during each exercise test was calculated either from resting HR in a sitting position (%HRRsitting), when lying awake (%HRRlying), or during sleep (%HRRsleeping). Differences between %VO2R and %HRR values were examined using Bland-Altman plots. A 180-day, 24/7%HRR measurement with three healthy adults was also conducted. The %HRR values during working days and holidays were compared.
Results:
In the treadmill testing, the mean difference between %VO2R and %HRRsleeping was 1.7% (95% confidence interval [CI], - 0.2 to 3.6%). The %HRRsitting and %HRRlying values were 10.8% (95% CI, 8.8 to 12.7%) and 7.7% (95% CI, 5.4 to 9.9%), respectively. In the 6MWT, mean differences between %VO2R and %HRRsitting, %HRRlying and %HRRsleeping were 12.7% (95% CI, 10.0 to 15.5%), 7.0% (95% CI, 4.0 to 10.0%) and - 2.9% (95% CI, - 5.0% to - 0.7%), respectively. The 180-day, 24/7%HRR measurement presented significant differences in %HRR patterns between working days and holidays in all three participants.
Conclusions:
The results suggest %HRRsleeping is valid in comparison to %VO2R. The results may encourage a calibration-less, 24/7 measurement model of exercise intensity using wearable devices.
Trial Registration:
UMIN000034967.Registered 21 November 2018 (retrospectively registered).
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...