Related Experiment Video
Updated: Jan 4, 2026

Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
Published on: July 27, 2018
Investigating Charge Transfer Interactions in AuCe2O Clusters Using Photoionization Efficiency Spectroscopy and
Robert A Hardy1, Aidan M Karayilan1, Gregory F Metha1
1Department of Chemistry , The University of Adelaide , Adelaide , South Australia 5005 , Australia.
Abstract:
The properties of small cerium oxide and gold-cerium oxide clusters were explored as analogues for gold deposition at defect sites on a cerium oxide surface. Ce2O (n = 0-2) and AuCe2O (n = 0-2) clusters were prepared in the gas phase and investigated using photoionization efficiency spectroscopy complemented by spectral simulations based on DFT calculations; purely theoretical investigations were conducted on the Ce2O3, Ce2O4, AuCe2O3, and AuCe2O4 clusters due to these species not being detected. The optimized AuCe2O (n = 0-3) cluster geometries are consistent with Au adsorption to oxygen vacancy sites while the AuCe2O4 cluster correlates with Au adsorption to a CeO2 vacancy site. The electronic properties of the adsorbed Au atom depend strongly on the nature of the ceria adsorption site: O vacancy-adsorbed Au is negatively charged with a Ce → Au charge transfer occurring at the adsorption interface, whereas Au adsorbed to a CeO2 vacancy is positively charged with an Au → Ce charge transfer. The adsorbed Au atom is proposed to enhance the catalytic properties of the AuCe2O cluster by (i) stabilizing the negatively charged Au atom on reduced AuCe2O clusters to enhance nucleophilicity; (ii) increasing the electron accepting capability of the AuCe2O4 species; (iii) destabilizing the HOMO of the AuCe2O4 cluster; and (iv) facilitating the abstraction of additional surface oxygen atoms by reactants.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
08:51Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
Published on: August 18, 2017
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Atomization Methods