Incredulity on assumptions for the simplified Bohart-Adams model: 17a-ethinylestradiol separation in lab-scale
Jing He1, Qiuhong Zhou1, Jinsong Guo1
1Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Ministry of Education, Chongqing University, Chongqing 400045, China; Faculty of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400045, China.
Abstract:
In this study, the original Bohart-Adams model was employed to analyze the experimental data of 17α-ethinylestradiol (EE2) separation in lab-scale anthracite columns with low initial concentration. Besides, the assumptions for the simplified Bohart-Adams model were calculated and discussed. The results revealed that the breakthrough curves of EE2 separation in anthracite columns under different conditions were asymmetrical N-shaped and could be divided into three parts. The third part of the breakthrough curves was successfully fitted by the original Bohart-Adams model with high R2 values (higher than 0.918) and low ARS values (less than 0.141). As expected, the assumptions for the simplified Bohart-Adams model were not tenable during the whole experiment process. As a result, the EE2 separation capacities (N0° and N0s) obtained from the original and simplified Bohart-Adams model were quite different, and most N0° values were greater than N0s values. The N0° value used to evaluate the pollutant separation capacity in lab-scale column would be more accurate. In addition, physical interception and chemical adsorption simultaneously worked in the EE2 separation in anthracite columns. Physical interception and bed depth in anthracite columns at low flow rate were related in quadratic function (R2 > 0.988).
Related Concept Videos
Analyte Adsorption and Distribution
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Principles Of Column Chromatography
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Types Of Column Chromatography
Gel Filtration Chromatography
When the...