Background:
Temporary mechanical circulatory support (MCS) devices provide hemodynamic assistance for shock refractory to pharmacological treatment. Most registries have focused on single devices or specific etiologies of shock, limiting data regarding overall practice patterns with temporary MCS in cardiac intensive care units.
Methods:
The CCCTN (Critical Care Cardiology Trials Network) is a multicenter network of tertiary CICUs in North America. Between September 2017 and September 2018, each center (n=16) contributed a 2-month snapshot of consecutive medical CICU admissions.
Results:
Of the 270 admissions using temporary MCS, 33% had acute myocardial infarction-related cardiogenic shock (CS), 31% had CS not related to acute myocardial infarction, 11% had mixed shock, and 22% had an indication other than shock. Among all 585 admissions with CS or mixed shock, 34% used temporary MCS during the CICU stay with substantial variation between centers (range: 17%-50%). The most common temporary MCS devices were intraaortic balloon pumps (72%), Impella (17%), and veno-arterial extracorporeal membrane oxygenation (11%), although intraaortic balloon pump use also varied between centers (range: 40%-100%). Patients managed with intraaortic balloon pump versus other forms of MCS (advanced MCS) had lower Sequential Organ Failure Assessment scores and less severe metabolic derangements. Illness severity was similar at high- versus low-MCS utilizing centers and at centers with more advanced MCS use.
Conclusions:
There is wide variation in the use of temporary MCS among patients with shock in tertiary CICUs. While hospital-level variation in temporary MCS device selection is not explained by differences in illness severity, patient-level variation appears to be related, at least in part, to illness severity.
More Related Videos
Related Concept Videos
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Cardiopulmonary Resuscitation IV: Pharmacological Management
Heart Failure VI: Adjunct Therapies
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiomyopathy II: Dilated Cardiomyopathy
Continuous Renal Replacement Therapy