Related Experiment Video
Updated: Jan 4, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Quantitative response in ion mobility spectrometry with atmospheric pressure chemical ionization in positive polarity
Zahra Safaei1, Timothy J Willy2, Gary A Eiceman3
1Department of Green Chemistry, LUT University, Sammonkatu 12, FI-50130, Mikkeli, Finland; Department of Chemistry and Biochemistry, 1175 North Horseshoe Drive, New Mexico State University, Las Cruces, NM, 88003, USA.
Abstract:
Response of an ion mobility spectrometer at ambient pressure was quantitatively determined for fourteen chemicals from five chemical families spanning a range of proton affinities and temperature from 30 to 175 °C with moisture from 1 to 1 × 104 ppmv in purified air. Peak intensities, drift times and reduced mobility coefficients were determined for hydrated protons from a63Ni ion source and for protonated monomers and proton bound dimers of alcohols, aldehydes, acetates, ketones, and organophosphates. These measurements permitted the determination of response factors with atmospheric pressure chemical ionization and the influence of moisture and temperature on APCI response with correlation to computational models of hydration values. The formation of protonated monomers and proton bound dimers was described by heats of formation for a displacement reaction of water on H+(H2O)n by an analyte vapor and favorably matched results from density functional theory (DFT) with the 6-311 + G(dp) basis set. Response factors worsened with increased moisture and decreased temperature for compounds of medium, and more so, of low proton affinities. Findings here provide a broad measure and understanding for quantitative response in ion mobility spectrometers for substances for combinations of moisture and temperature.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Overview
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: