Related Experiment Video
Updated: Jan 4, 2026

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Regional characteristics of NO2 column densities from Pandora observations during the MAPS-Seoul campaign
Heesung Chong1, Hana Lee1, Ja-Ho Koo1
1Department of Atmospheric Sciences, Yonsei University, Seoul, South Korea.
Abstract:
Vertical column density (VCD) of nitrogen dioxide (NO2) was measured using Pandora spectrometers at six sites on the Korean Peninsula during the Megacity Air Pollution Studies-Seoul (MAPS-Seoul) campaign from May to June 2015. To estimate the tropospheric NO2 VCD, the stratospheric NO2 VCD from the Ozone Monitoring Instrument (OMI) was subtracted from the total NO2 VCD from Pandora. European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis wind data was used to analyze variations in tropospheric NO2 VCD caused by wind patterns at each site. The Yonsei/SEO site was found to have the largest tropospheric NO2 VCD (1.49 DU on average) from a statistical analysis of hourly tropospheric NO2 VCD measurements. At rural sites, remarkably low NO2 VCDs were observed. However, a wind field analysis showed that trans-boundary transport and emissions from domestic sources lead to an increase in tropospheric NO2 VCD at NIER/BYI and KMA/AMY, respectively. At urban sites, high NO2 VCD values were observed under conditions of low wind speed, which were influenced by local urban emissions. Tropospheric NO2 VCD at HUFS/Yongin increases under conditions of significant transport from urban area of Seoul according to a correlation analysis that considers the transport time lag. Significant diurnal variations were found at urban sites during the MAPS-Seoul campaign, but not at rural sites, indicating that it is associated with diurnal patterns of NO2 emissions from dense traffic.
Related Concept Videos
Types of Global Positioning System Surveys
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Selected Data About Geographic Locations
Cluster Sampling Method
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...
Noble Gases
The elements in group 18 are noble gases (helium, neon, argon, krypton, xenon, and radon). They earned the name “noble” because they were assumed to be nonreactive since they have filled valence shells. In 1962, Dr. Neil Bartlett at the University of British Columbia proved this assumption to be false.
Emission Spectra