Institutionally Based ImPACT Test® Normative Values May Differ from Manufacturer-Provided Normative Values.
Samuel R Walton1,2, Donna K Broshek3, Jason R Freeman4
1Department of Kinesiology, University of Virginia, Charlottesville, VA 22903, USA.
Comparing post-concussion Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) results to institution-specific norms, not manufacturer data, is crucial. This study found significant differences, highlighting the risk of misclassifying neurocognitive impairment in athletes.
Area of Science:
- Sports Medicine
- Neuroscience
- Clinical Psychology
Background:
- Computerized neurocognitive assessments are used to evaluate concussions.
- The validity of using manufacturer-provided normative data versus institution-specific data for post-concussion assessment is debated.
- Manufacturer norms may not accurately reflect the performance of specific athlete populations.
Purpose of the Study:
- To compare institutionally derived normative data with manufacturer-provided normative data from ImPACT® Applications.
- To assess the potential for misclassification of neurocognitive impairment in collegiate athletes.
- To evaluate the utility of baseline testing versus manufacturer norms for concussion management.
Main Methods:
- A cohort study involving 952 NCAA Division 1 university student athletes.
- Participants completed baseline Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) assessments.
- Data were analyzed by comparing institutionally derived norms to manufacturer norms for ImPACT clinical composite scores (Verbal Memory, Visual Memory, Visual Motor Speed, Reaction Time) using Chi-squared analysis.
Main Results:
- Institutionally derived norms showed significantly different performance distributions compared to manufacturer norms (p < 0.001).
- Athletes performed above average on Verbal Memory, Visual Memory, and Visual Motor Speed, and slightly below average on Reaction Time when compared to manufacturer data.
- Significant differences were observed across all ImPACT clinical composite scores.
Conclusions:
- There are significant differences between manufacturer-provided and institutionally derived normative data for ImPACT assessments.
- Using manufacturer norms may lead to an increased risk of misclassifying neurocognitive impairment in athletes post-concussion.
- The study supports the use of institutionally derived norms or baseline testing for accurate concussion assessment.
Related Concept Videos
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Significance Testing: Overview
Bioequivalence Data: Statistical Interpretation
Clinically Relevant Drug Product Specifications: Methods of Establishment
Testing Water Quality
Testing a Claim about Mean: Unknown Population SD
Estimating a population mean requires the samples to be approximately normally distributed. The data should be collected from the randomly selected samples having no sampling bias. There is no specific requirement for sample size. But if the sample size is less than 30, and we don't know the population standard deviation, a different approach is used;...