Related Experiment Video
Updated: Jan 4, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
LOW DOSE BATH FROM IMPT VS. IMXT FOR THE PELVIC AREA WHEN TREATING ADVANCED PROSTATE CANCER
Matěj Navrátil1,2, Vladimír Vondráček1,2, Michal Andrlík1,2
1Proton Therapy Center Czech, Budínova 1a, 18000 Prague 8, Czech Republic.
Abstract:
Twenty (10 intensity-modulated proton therapy (IMPT) and 10 intensity-modulated x-ray therapy (IMXT) treatment plans for patients with advanced prostate carcinoma were compared in this study. All chosen patients were indicated for prostate and pelvic lymph nodes irradiation using simultaneous integrated boost technique. These patients represent typical specimen for this diagnose. IMPT irradiates just half of the tissue volume with a low dose (up to 10 cobalt gray equivalent) compared to IMXT without compromise in target volumes coverage and in this way reduces the risk of secondary cancer development or other possible complications.
More Related Videos
07:25A Bioluminescent and Fluorescent Orthotopic Syngeneic Murine Model of Androgen-dependent and Castration-resistant Prostate Cancer
Published on: March 6, 2018
04:04Endobronchial Ultrasound-guided Intratumoral Injection of Cisplatin for the Treatment of Isolated Mediastinal Recurrence of Lung Cancer