Wound monitoring of pH and oxygen in patients after radiation therapy
Steffen Auerswald1, Stephan Schreml2, Robert Meier3
1Department of Otorhinolaryngology, University Medical Center Regensburg, Regensburg, Germany.
Objectives:
Postradiogenic wound healing disorders are an important clinical problem. While a variety of treatment modalities are available, there is no strategy to objectively judge treatment success. The aim of this study was to evaluate a 2D luminescence imaging system for pH and oxygen in non-healing wounds after radiotherapy.
Methods:
Luminescence 2D imaging was performed with the VisiSens (Presens, Regensburg, Germany) 2D imaging systems A1 and A2 for oxygen and pH, respectively. Biocompatible planar luminescent sensor foils were applied to non-irradiated and irradiated skin as well as to radiogenic wounds of five patients and the pH and the oxygen saturation was determined.
Results:
pH measurements showed significant differences between non-irradiated skin (6.46 ± 0.18) and irradiated skin (6.96 ± 0.26). Radiogenic wounds exhibited the highest pH values (7.53 ± 0.26). Oxygen measurements revealed a mean oxygen saturation of non-irradiated skin of 6.19 ± 0.83 mmHg. The highest value of oxygen saturation (28.4 ± 2.4 mmHg) was found on irradiated skin while irradiated wounds had a poor oxygen saturation (9.4 ± 2.2 mmHg) (mean ± s.e.m.).
Conclusion:
We found that routine measurement of pH and pO2 in patients could be easily integrated into the clinical routine. The results of the measurements show unfavorable pH and oxygen saturation conditions for wound healing in irradiated wounds. Interestingly, irradiated wounds exhibit a more pronounced hypoxia than irradiated skin which is reflected by an altered pH and pO2 compared to unirradiated skin, which has the potential to serve as a prognostic marker in the future. In addition to the objectification of the treatment success of postradiogenic wound healing disorders, the extent of skin toxicity could already be predicted during radiotherapy with this method.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...


