Related Experiment Video
Updated: Jan 4, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
The risk of tooth root injuries using cortical screws for intermaxillary fixation and osteosynthesis plates - A
Andreas Max Pabst1, Sebastian Blatt2, Pia Epperlein2
1Department of Oral- and Maxillofacial Surgery, Federal Armed Forces Hospital, (Head: Prof. Dr. Dr. R. Werkmeister), Rübenacherstrasse 170, 56072 Koblenz, Germany; Department of Oral- and Maxillofacial Surgery, University Medical Center, (Head: Univ.-Prof. Dr. Dr. B. Al-Nawas), Augustusplatz 2, 55131 Mainz, Germany.
Abstract:
Intermaxillary fixation (IMF) and osteosynthesis plates (OP) are widely used for the non-surgical and surgical treatment of mandible and condyle fractures. The aim of this retrospective study was to analyze the frequency of tooth root injuries by IMF and OP screws. Electronic patient reports (2004-2013) were screened for patients treated with either IMF screws and/or OP in the Department of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Germany. The frequency and the position of endangered and injured teeth were analyzed by orthopantomogram (OPTG) and cone beam computer tomography (CBCT). Next, possible predictive factors for tooth root injuries, namely interdental- and crestal distance, screw length and distance between tooth root and screw were evaluated. Further, the accuracy of OPTG vs. CBCT concerning the diagnosis of tooth root injuries was analyzed. Three-hundred sixty-six patients were included and 3388 teeth were defined as endangered by IMF- and OP screws. Overall, 16 injured teeth (0.5%) in 13 patients (3.55%) were detected. Nine injuries (56.3%) were caused by IMF- and seven injuries (43.8%) by OP screws. Three teeth were non-vital, one tooth had to be extracted. No correlation between the predictive factors crestal distance, screw length and tooth root injuries was found. If tooth injury occurred, a significant correlation between the interdental distance and the distance between tooth root and screw was found (κ = 0.48; p < 0,0001). Comparison between OPTG vs. CBCT demonstrated that many of the injuries that were seen in the OPTG (n = 230) could not be verified in the CBCT scans (n = 16) (κ = 0.12). To conclude, screws for IMF and OP can be considered as a safe procedure concerning the risk of tooth root injuries.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021