Related Experiment Video
Updated: Jan 4, 2026

Endovascular Perforation Model for Subarachnoid Hemorrhage Combined with Magnetic Resonance Imaging MRI
Published on: December 16, 2021
Quantification of Carotid Intraplaque Hemorrhage: Comparison between Manual Segmentation and Semi-Automatic
Young Ju Song1, Hyo Sung Kwak2, Gyung Ho Chung2
1Department of Radiology of Chonbuk National University Hospital, Jeon-ju 54907, Korea.
Purpose:
Carotid intraplaque hemorrhage (IPH) increases risk of territorial cerebral ischemic events, but different sequences or criteria have been used to diagnose or quantify carotid IPH. The purpose of this study was to compare manual segmentation and semi-automatic segmentation for quantification of carotid IPH on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequences.
Methods:
Forty patients with 16-79% carotid stenosis and IPH on MPRAGE sequences were reviewed by two trained radiologists with more than five years of specialized experience in carotid plaque characterization with carotid plaque MRI. Initially, the radiologists manually viewed the IPH based on the MPRAGE sequence. IPH volume was then measured by three different semi-automatic methods, with high signal intensity 150%, 175%, and 200%, respectively, above that of adjacent muscle on the MPRAGE sequence. Agreement on measurements between manual segmentation and semi-automatic segmentation was assessed using the intraclass correlation coefficient (ICC).
Results:
There was near-perfect agreement between manual segmentation and the 150% and 175% criteria for semi-automatic segmentation in quantification of IPH volume. The ICC of each semi-automatic segmentation were as follows: 150% criteria: 0.861, 175% criteria: 0.809, 200% criteria: 0.491. The ICC value of manual vs. 150% criteria and manual vs. 175% criteria were significantly better than the manual vs. 200% criteria (p < 0.001).
Conclusions:
The ICC of 150% and 175% criteria for semi-automatic segmentation are more reliable for quantification of IPH volume. Semi-automatic classification tools may be beneficial in large-scale multicenter studies by reducing image analysis time and avoiding bias between human reviewers.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
08:12A Volumetric Method for Quantification of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage
Published on: July 28, 2018