Comparison of two experimental ARDS models in pigs using electrical impedance tomography
Nadine Hochhausen1, Jakob Orschulik2, Andreas Follmann1
1Department of Anesthesiology, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Plos One
|November 14, 2019
Summary
Electrical impedance tomography (EIT) shows different results in acute respiratory distress syndrome (ARDS) models. The lavage model, unlike the LPS model, initially affected global inhomogeneity and regional ventilation delay indices.
Area of Science:
- Medical science
- Physiology
- Medical imaging
Background:
- Animal models are crucial for medical advancements.
- The lavage model is common for studying acute respiratory distress syndrome (ARDS) with electrical impedance tomography (EIT).
- The lavage model may systematically impact EIT parameters, necessitating alternative models like lipopolysaccharide (LPS)-induced ARDS.
Purpose of the Study:
- To compare EIT measurements in lavage-induced versus LPS-induced ARDS models.
- To determine if ARDS pathophysiology influences EIT-derived indices.
- To assess the consistency of global inhomogeneity (GI) and regional ventilation delay (RVD) indices between models.
Main Methods:
- Nineteen pigs were divided into control, lavage, and LPS groups.
- ARDS was induced, followed by hourly assessments over eight hours.
- Respiratory mechanics, hemodynamics, gas exchange, and EIT recordings were analyzed.
Main Results:
- EIT measurements were reliable in both ARDS models.
- Initially, the lavage group showed higher GI and RVD indices than the control and LPS groups.
- These differences diminished over time, and LPS-induced ARDS maintained more stable clinical lung injury parameters.
Conclusions:
- The two ARDS models exert different influences on GI and RVD indices.
- Underlying pathophysiology significantly affects EIT parameters.
- Findings suggest limitations in translating EIT-guided ARDS therapy from animal models to human patients.