Related Experiment Video
Updated: Jan 3, 2026

Author Spotlight: A Comprehensive Protocol for Acinetobacter Biofilm Quantification, Assessment, and Visualization
Published on: August 4, 2023
Environmental contamination by carbapenem-resistant Acinetobacter baumannii: The effects of room type and cleaning
Anat Or Lerner1, Jalal Abu-Hanna1, Yehuda Carmeli2,3
1Division of Epidemiology and Preventive Medicine, Tel Aviv Sourasky Medical Centre, Tel Aviv, Israel.
Objective:
We evaluated environmental contamination by carbapenem-resistant Acinetobacter baumannii (CRAB), the effectiveness of cleaning practices, the performance of aerosolized hydrogen-peroxide (aHP) technology, and the correlation between measures of cleaning and environmental contamination.
Design:
Serial testing of environmental contamination during a 7-month period.
Setting:
Single-patient rooms in intensive care units (ICUs) and multipatient step-up and regular rooms in internal medicine wards in a tertiary-care hospital with endemic CRAB.
Methods:
CRAB environmental contamination was determined semiquantitatively using sponge sampling.
Results:
In step-up rooms, 91% of patient units (56% of objects) were contaminated, and half of them were heavily contaminated. In regular rooms, only 21% of patient units (3% of objects) were contaminated. In ICUs, 76% of single-patient rooms (24% of objects) were contaminated. Cleaning did not reduce the number of contaminated objects or patient units in step-up rooms. After refresher training, cleaning reduced the proportion of contaminated objects by 2-fold (P = .001), but almost all patient units remained contaminated. Using aerosolized hydrogen peroxide (aHP) disinfection after discharge of a known CRAB-carrier decreased room contamination by 78%, similar to the reduction achieved by manual hypochloride cleaning. Measuring cleaning efficacy using fluorescent gel did not correlate with recovery of CRAB by sponge cultures.
Conclusions:
In step-up rooms, the high number of objects contaminated combined with poor efficacy of cleaning resulted in failure to eliminate CRAB in patient units. Fluorescent gel is a poor detector of CRAB contamination. The role of aHP is still unclear. However, its use in multipatient rooms is limited because it can only be used in unoccupied rooms.
More Related Videos
09:30Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
09:29In Vivo Investigation of Antimicrobial Blue Light Therapy for Multidrug-resistant Acinetobacter baumannii Burn Infections Using Bioluminescence Imaging
Published on: April 28, 2017
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Antimicrobial Effectiveness