Objective:
This study evaluated the clinical feasibility of a new low-cost TomoTherapy system (OnradTM) and compared it with low-cost linear accelerator models (linacs).
Methods:
Various aspects of treatment and cost were compared between Onrad and linacs for 3-dimensional radiotherapy (3DCRT). Dosimetric comparisons of 10 patients each with breast, stage III lung, prostate, head and neck, and cervical cancers were carried out (total 100 plans).
Results:
Onrad had advantages in terms of availability of long treatment fields and a smaller mechanical footprint. For breast cancers and lung cancers, target dose homogeneity in Onrad plans was better than that in 3DCRT. In the prostate plans, Onrad plans provided superior D95, conformity and homogeneity. The rectum doses of Onrad plans were lower than those with 3DCRT. Onrad plans provided superior homogeneity and D95 in head and neck cancer. The mean dose and V10-40 Gy of the parotid glands was lower using Onrad. In the cervical cancer plans, target doses were similar with both systems. Normal tissue doses were equal.
Conclusions:
Onrad is useful in the clinical setting. Onrad can achieve favorable or comparable dose distributions compared with those of 3DCRT in actual clinical treatment of breast, lung, prostate, head and neck, and cervical cancers.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...