Global and Regional Ventilation during High Flow Nasal Cannula in Patients with Hypoxia
Dong Hyun Lee1, Eun Young Kim2, Ga Jin Seo2
1Department of Pulmonology and Intensive Care Medicine, Dong-A University Hospital, Dong-A University College of Medicine, Busan, Korea.
Background:
High flow nasal cannula (HFNC) is known to increase global ventilation volume in healthy subjects. We sought to investigate the effect of HFNC on global and regional ventilation patterns in patients with hypoxia.
Methods:
Patients were randomized to receive one of two oxygen therapies in sequence: nasal cannula (NC) followed by HFNC or HFNC followed by NC. Global and regional ventilation was assessed using electric impedance tomography.
Results:
Twenty-four patients participated. Global tidal variation (TV) in the lung was higher during HFNC (NC, 2,241 ± 1,381 arbitrary units (AU); HFNC, 2,543 ± 1,534 AU; P < 0.001). Regional TVs for four iso-gravitational quadrants of the lung were also all higher during HFNC than NC. The coefficient of variation for the four quadrants of the lung was 0.90 ± 0.61 during NC and 0.77 ± 0.48 during HFNC (P = 0.035). Within the four gravitational layers of the lung, regional TVs were higher in the two middle layers during HFNC when compared to NC. Regional TV values in the most ventral and dorsal layers of the lung were not higher during HFNC compared with NC. The coefficient of variation for the four gravitational layers of the lung were 1.00 ± 0.57 during NC and 0.97 ± 0.42 during HFNC (P = 0.574).
Conclusions:
In patients with hypoxia, ventilation of iso-gravitational regions of the lung during HFNC was higher and more homogenized compared with NC. However, ventilation of gravitational layers increased only in the middle layers. (Clinical trials registration number: NCT02943863).
More Related Videos
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation I: Indication and Settings
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...