Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
Alberto Cresti1, Pasquale Baratta1, Francesco De Sensi1
1Cardio-Neurovascular Department, Misricordia Hospital, Grosseto, Italy.
Background:
The avascular region of the fibrous body between the mitral and aortic valves, named mitral-aortic intervalvular fibrosa (MAIVF), is often involved in the periaortic diffusion of infective endocarditis (IE), resulting in abscess or pseudoaneurysm formation. The early recognition of these life-threatening complications is of crucial importance, as urgent surgical correction is necessary. In the first stages of the abscess formation, the only sign is an increased thickness of the MAIVF. To the best of our knowledge, normal transesophageal echocardiography (TEE) examination reference values for MAIVF thickness has not yet been established. The aim of the study was to define the normal ranges of MAIVF thickness in a population of healthy adults who underwent a TEE examination.
Materials And Methods:
A population of consecutive adult patients who underwent a TEE examination was enrolled in the study. Measurement was performed in short-axis (SAX) and long-axis (LAX) views. Mean-2 standard deviations (mean-2SDs) and 5%, 10%, 90%, and 95% confidence intervals were evaluated. A comparison with MAIVF thickness in patients affected by aortic IE complicated by abscess formation was performed, and receiver operating characteristic (ROC) curves were constructed to achieve the optimal cutoff value of normality.
Results:
A total of 477 consecutive Caucasian adult patients were enrolled (mean age: 69 years, range: 27-93 years). Mean-2SD MAIVF measurement in SAX view was 0.325 cm (95% confidence interval [CI]: 0.319-0.330 cm) and in LAX view was 0.340 cm (95% CI: 0.334-0.346 cm). Computed tomography-MAIVF mean measurement (±2SD) was 0.237 cm (95% CI: 0.110-0.340 cm). ROC curves showed that a cutoff SAX value measurement of 0.552 (area under the curve [AUC]: 95.2%) had a sensibility of 88.2% and a specificity of 92.4%; a LAX measurement value of 0.623 (AUC: 93.3%) had a sensibility of 82.7% and a specificity of 85.7%. The multivariate analysis showed no significant correlation between MAIVF thickness, age, and sex.
Conclusion:
In healthy patients, MAIVF thickness should not exceed 0.600 cm. Above these values, the suspicion of a periaortic abscess formation should be raised. MAIVF increased thickness may be an early sign of perivalvular diffusion requiring an urgent endocarditis team evaluation.
Insights
Normal mitral-aortic intervalvular fibrosa (MAIVF) thickness in healthy adults is under 0.600 cm. Increased MAIVF thickness may indicate early periaortic abscess formation from infective endocarditis, requiring prompt evaluation.
Area of Science:
- Cardiology
- Medical Imaging
- Infectious Diseases
Background:
- The mitral-aortic intervalvular fibrosa (MAIVF) is a critical area prone to infective endocarditis (IE) complications like abscesses.
- Early detection of MAIVF thickening is vital for timely intervention in IE cases.
- Establishing normal MAIVF thickness reference values is essential for accurate diagnosis.
Purpose of the Study:
- To define the normal reference ranges for MAIVF thickness using transesophageal echocardiography (TEE) in healthy adults.
- To establish diagnostic criteria for identifying MAIVF abnormalities indicative of IE complications.
Main Methods:
- Consecutive adult patients undergoing TEE were enrolled.
- MAIVF thickness was measured in short-axis (SAX) and long-axis (LAX) views.
- Statistical analysis included mean-2SD, confidence intervals, and ROC curves to determine optimal cutoff values.
Main Results:
- Normal MAIVF thickness in SAX view was 0.325 cm and in LAX view was 0.340 cm (mean-2SD).
- ROC analysis identified SAX cutoff of 0.552 cm (95.2% AUC) and LAX cutoff of 0.623 cm (93.3% AUC).
- No significant correlation was found between MAIVF thickness, age, or sex.
Conclusions:
- Normal MAIVF thickness in healthy individuals should not exceed 0.600 cm.
- MAIVF thickness above this threshold warrants suspicion for periaortic abscess formation.
- Increased MAIVF thickness is a potential early indicator of perivalvular IE requiring urgent specialist evaluation.