Related Experiment Video
Updated: Jan 3, 2026

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Ingestible sensors correlate closely with peripheral temperature measurements in febrile patients
Fanyu Huang1, Chloe Magnin1, Philippe Brouqui1
1Department of Research Microbes Evolution Phylogeny and Infections (MEPHI), The Institute for Development Research (IRD), University Hospital Institute-Mediterranean infection, Aix Marseille University, 19-21 Boulevard Jean MOULIN, 13005 Marseille, France.
Backgrounds:
Reliable non-invasive methods for measuring body temperature are essential for the diagnosis and monitoring of infectious disease.
Methods:
This study used Intraclass Correlation Coefficients (ICC) and the Bland- Altman plot to analyse the agreement between temperature measurements using an ingestible capsule sensor, a skin sensor and two non-invasive peripheral temperature measurements (axillary and infrared non-contact), collected from a population of febrile patient admitted for infectious disease.
Results:
Of the 77 febrile patients screened, 26 patients were enrolled. The ICC between axillary temperature measurements (Taxi) vs. non-contact measurements (Tno-c) were 0.34 [-0.18; 0.63], 0.87 [0.55; 0.94] between Taxi vs. ingestible capsule measurements (Tcap) and 0.12 [-0.09; 0.37] between Taxi vs. Tetac. The mean difference between Taxi vs Tno-c was -1.18 °C with limits of agreement (LoA) from -2.96 to 0.58 °C. The mean difference between Taxi vs Tcap was 0.48 °C, with LoA from -0.60 to 1.56 °C. The mean difference between Taxi vs Tetac was -4.23 °C with LoA from -7.22 to -1.23 °C.
Conclusions:
Ingestible capsule measurements are reliable enough to adequately estimate the core body temperature in clinical practice. Its non-invasiveness, and the real-time remote control offer new opportunities for future research into fever during infectious diseases.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Increased Body Temperature
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...