Monitoring respiratory rates with a wearable system using a stretchable strain sensor during moderate exercise
Akio Yamamoto1, Hiroyuki Nakamoto2, Yusuke Bessho3
1Department of Community Health Sciences, Graduate School of Health Sciences, Kobe University, 7-10-2 Tomogaoka, Suma-ku, Kobe-si, Hyogo, 654-0142, Japan. fon175@osaka-med.ac.jp.
Abstract:
Respiratory rate, a sensitive indicator of respiratory status, is rarely measured during the field walking test. Our objective was to develop and validate a non-invasive, wearable monitoring system using stretchable strain sensors and an accompanying algorithm capable of providing real-time measurements of respiration during exercise. Twenty-four healthy volunteers wore stretchable sensors during a walking test protocol that included standing, sitting, walking, and walking with a stick. Sensors were placed on the ribcage and abdomen. The Bland-Altman method was used to assess the accuracy and precision of breath counts; total respiration time and inspiration time ratio were determined by custom algorithms and compared with measurements obtained with the standard flow sensor. The output signal from the stretchable sensor was highly synchronized with flow signals. The limits of agreement were within 3 breaths/min throughout the test protocol. Differences between sensors for total respiration time and inspiration time ratio were less than 14% and 26%, respectively. The agreement was maintained regardless of respiratory rate or volume. The wearable respiratory monitoring system yielded accurate and precise breath counts and total duration of respiratory cycle during moderate exercise in healthy young individuals, suggesting that it might be useful in clinical practice. Graphical abstract.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...