Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Modified arytenoid muscle electrode recording method for neuromonitoring during thyroidectomy
Peng Li1, Qing-Zhuang Liang1, Dong-Lai Wang1
1Department of Thyroid and Parathyroid Surgery, Peking University Shenzhen Hospital, Peking University Health Science Center, Shenzhen 518000, China.
This study found that a modified arytenoid muscle electromyography (EMG) recording method is safe and reliable for protecting the recurrent laryngeal nerve (RLN) during thyroid surgery. The modified method revealed differences in EMG signal latency between the right and left vagus nerves.
Area of Science:
- Neurosurgery
- Otolaryngology
- Anesthesiology
Background:
- Intraoperative neuromonitoring (IONM) is crucial for recurrent laryngeal nerve (RLN) protection during thyroidectomy.
- Arytenoid muscle electromyography (EMG) recording is a feasible method, but signal parameters require further analysis.
- Modifying needle electrode insertion direction can optimize EMG signal characteristics.
Purpose of the Study:
- To analyze clinical characteristics of EMG signal parameters by altering needle electrode insertion direction.
- To evaluate the safety, feasibility, and reliability of a modified arytenoid muscle EMG recording technique.
- To investigate potential differences in EMG parameters between different sides and patient demographics.
Main Methods:
- Recruited 92 patients undergoing thyroidectomy.
- Inserted paired needle electrodes into bilateral cricothyroid muscle and thyroid cartilage junctions.
- Recorded EMG signals using a four-step method (V1-R1-R2-V2) and confirmed vocal cord function via laryngo-fiberoscopy.
Main Results:
- Successfully recorded 122 RLNs, with no significant changes in EMG amplitude or latency before and after resection.
- Observed normal vocal cord movement postoperatively.
- Found higher amplitude in left nerves compared to right, and shorter latency in right vagus nerves than left.
Conclusions:
- The modified arytenoid muscle EMG recording method is safe, feasible, and reliable for RLN monitoring.
- EMG signal latency differs between right and left vagus nerves.
- EMG signal amplitude may be influenced by the side of nerve recording.