Related Experiment Video
Updated: Jan 3, 2026

Production and Measurement of Organic Particulate Matter in the Harvard Environmental Chamber
Published on: November 18, 2018
Comparison of 4 Methods for Measurement of Reactive, Gaseous Oxidized, and Particulate Bound Mercury
Mae Sexauer Gustin1, Sarrah M Dunham-Cheatham1, Lei Zhang2
1Department of Natural Resources and Environmental Science , University of Nevada, Reno , Reno , Nevada 89557 , United States.
Abstract:
The atmosphere is an important (1) pathway by which mercury (Hg) is transported around the globe and (2) source of Hg to ecosystems. Thus, understanding Hg atmospheric chemistry is critical for understanding the biogeochemical cycle and impacts to human and ecosystem health. Work over the past 13 years has demonstrated that the standard instrument used to measure atmospheric Hg does not accurately quantify gaseous oxidized mercury (GOM) or particulate bound mercury (PBM). This study focused on comparing four methods for quantifying atmospheric Hg and identifying Hg(II) compounds. Data from two automated systems, the Tekran 2537/1130 system and the University of Nevada, Reno-Dual Channel System (DCS), were compared with two University of Nevada, Reno-Reactive Mercury Active Systems (RMAS 2.0). One RMAS 2.0 included cation exchange membranes (CEMs) and nylon membranes, and the second included a polytetrafluoroethylene (PTFE) membrane upstream of the CEM and nylon membranes. The Tekran system and the DCS underestimated GOM concentrations with respect to that measured using the RMAS 2.0. The RMAS 2.0 with the upstream PTFE provided a means of distinguishing GOM and PBM. Thermal desorption of nylon membrane data identified a variety of GOM and PBM compounds present.
Related Concept Videos
The Scientific Method
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...