Related Experiment Video
Updated: Jan 3, 2026

Bronchial Thermoplasty: A Novel Therapeutic Approach to Severe Asthma
Published on: November 4, 2010
A Prospective, Ex Vivo Trial of Endobronchial Blockade Management Utilizing 3 Commonly Available Bronchial Blockers
Christopher R Gilbert1, Christopher Mallow2, Candice L Wishire1
1From the Thoracic Surgery and Interventional Pulmonology, Swedish Cancer Institute, Seattle, Washington.
Background:
Lung isolation with bronchial blockers is a well-described and accepted procedure, often described for use during the management of massive hemoptysis. Recommendations for balloon inflation are sparse, with some advocating for saline whereas other suggest air, including the manufacturers. We sought to evaluate the optimal method for balloon inflation in an ex vivo trial.
Methods:
We performed a prospective trial utilizing 3 commercially available bronchial blockers commonly described for use in lung isolation and massive hemoptysis management. We utilized the Arndt Endobronchial Blocker (Cook Medical), the Cohen Tip Deflecting Endobronchial Blocker (Cook Medical), and the Fogarty Venous Thrombectomy Catheter (Edwards LifeSciences). Balloon size and deflation assessment were tested within 3 different scenarios comparing air versus saline.Welch t test was performed to compare means between groups, and a generalized estimating equation model was utilized to compare balloon diameter over time to account for correlation among repeated measures from the same balloon.
Results:
All 3 endobronchial blocker systems were observed in triplicate. During free-standing balloon inflation, all 3 endobronchial systems displayed a greater degree of balloon deflation over time with air as opposed to saline (P < .001). Within a stent-based model, inflation with air of all 3 endobronchial systems, according to manufacturer recommendations, demonstrated significantly decreased time until fluid transgression occurred when compared to a saline model (P < .001). Within a stent-based model, inflation with air, according to clinical judgment, demonstrated significantly decreased time until fluid transgression in the Arndt (P = .016) and the Fogarty (P < .001) system, but not the Cohen (P = .173) system, when compared with saline.
Conclusions:
The utilization of saline for balloon inflation during bronchial blockade allows for more consistent balloon inflation. The use of saline during balloon inflation appears to delay passive, spontaneous balloon deflation time when compared to air during a model of endobronchial blockade. The approach of saline inflation should be tested in humans to demonstrate the overall applicability and validity of the current findings.
Related Concept Videos
COPD: Management Using Bronchodilators and Corticosteroids
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Drugs Used in Lower Respiratory Disorders: Overview
Bronchodilators, the first step of respiration enhancement, come in various forms, each with its own mechanism...
Antiasthma Drugs: β2-Adrenoceptor Agonists
One class of bronchodilators includes β2-adrenoceptor agonists. These agents target the β2-adrenoceptors located on bronchial smooth muscle cells. By stimulating these receptors, β2-agonists induce...