Related Experiment Video
Updated: Jan 3, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Changes in Stroke Volume Variation Induced by Passive Leg Raising to Predict Fluid Responsiveness in Cardiac Surgical
Guo-Guang Ma1, Guo-Wei Tu1, Ji-Li Zheng2
1Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China.
Objectives:
Stroke volume variation (SVV) has been used to predict fluid responsiveness. The authors hypothesized the changes in SVV induced by passive leg raising (PLR) might be an indicator of fluid responsiveness in patients with protective ventilation after cardiac surgery.
Design:
A prospective single-center observational study.
Setting:
A single cardiac surgery intensive care unit at a tertiary hospital.
Participants:
A total of 123 patients undergoing cardiac surgery with hemodynamic instability. Tidal volume was set between 6 and 8 mL/kg of ideal body weight.
Interventions:
PLR maneuver, fluid challenge.
Measurements And Main Results:
SVV was continuously recorded using pulse contour analysis before and immediately after a PLR test and after fluid challenge (500 mL of colloid given over 30 min). Sixty-three (51.22%) patients responded to fluid challenge, in which PLR and fluid challenge significantly increased the SV and decreased the SVV. The decrease in SVV induced by PLR was correlated with the SV changes induced by fluid challenge. A 4% decrease in the SVV induced by PLR-discriminated responders to fluid challenge with an area under the curve of 0.90. The gray zone identified a range of SVV changes induced by PLR (between -3.94% and -2.91%) for which fluid responsiveness could not be predicted reliably. The gray zone included 15.45% of the patients. The SVV at baseline predicted fluid responsiveness with an area under the curve of 0.72.
Conclusions:
Changes in the SVV induced by PLR predicted fluid responsiveness in cardiac surgical patients with protective ventilation.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...