Assessment of the peripheral microcirculation in patients with and without shock: a pilot study on different methods
Roberto Rabello Filho1, Renato Carneiro de Freitas Chaves2,3, Murillo Santucci Cesar Assunção2
1Departamento de Terapia Intensiva, Hospital Israelita Albert Einstein, Av. Albert Einstein, 627/701, 5th Floor, São Paulo, 05651-901, Brazil. roberto.rabello@einstein.br.
Abstract:
Microvascular dysfunction has been associated with adverse outcomes in critically ill patients, and the current concept of hemodynamic incoherence has gained attention. Our objective was to perform a comprehensive analysis of microcirculatory perfusion parameters and to investigate the best variables that could discriminate patients with and without circulatory shock during early intensive care unit (ICU) admission. This prospective observational study comprised a sample of 40 adult patients with and without circulatory shock (n = 20, each) admitted to the ICU within 24 h. Peripheral clinical [capillary refill time (CRT), peripheral perfusion index (PPI), skin-temperature gradient (Tskin-diff)] and laboratory [arterial lactate and base excess (BE)] perfusion parameters, in addition to near-infrared spectroscopy (NIRS)-derived variables were simultaneously assessed. While lactate, BE, CRT, PPI and Tskin-diff did not differ significantly between the groups, shock patients had lower baseline tissue oxygen saturation (StO2) [81 (76-83) % vs. 86 (76-90) %, p = 0.044], lower StO2min [50 (47-57) % vs. 55 (53-65) %, p = 0.038] and lower StO2max [87 (80-92) % vs. 93 (90-95) %, p = 0.017] than patients without shock. Additionally, dynamic NIRS variables [recovery time (r = 0.56, p = 0.010), descending slope (r = - 0.44, p = 0.05) and ascending slope (r = - 0.54, p = 0.014)] and not static variable [baseline StO2 (r = - 0.24, p = 0.28)] exhibited a significant correlation with the administered dose of norepinephrine. In our study with critically ill patients assessed within the first twenty-four hours of ICU admission, among the perfusion parameters, only NIRS-derived parameters could discriminate patients with and without shock.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
10:27Real-Time Assessment of Spinal Cord Microperfusion in a Porcine Model of Ischemia/Reperfusion
Published on: December 10, 2020
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...