Related Experiment Video
Updated: Jan 3, 2026

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
Published on: April 13, 2016
Study of drug particle distributions within mini-tablets using synchrotron X-ray microtomography and superpixel image
Leonie Wagner-Hattler1, Gabriela Québatte1, Jennifer Keiser2
1Division of Pharmaceutical Technology, Department of Pharmaceutical Sciences, University of Basel, Switzerland.
Abstract:
Uniform drug distribution within fast disintegrating tablets is a key quality measure to ensure a reliable, steady, and targeted release of the contained active pharmaceutical ingredients. In this work, the drug particle distribution in mini-tablets was studied with synchrotron phase contrast X-ray microtomography. Mini-tablets had a weight of 9.5 mg and a drug load from 2.5% to 20%. Moxidectin, a drug used for treatment of parasitic infections, was used as a model compound. Drug content covered a range from 91% to 121% of the target dose. A linear iterative clustering (SLIC) superpixel method was used for segmentation, analysis, and visualization of the spatial distribution of individual tablet components (i.e., pores, excipients, and drug). Results show that the drug was not uniformly distributed within the tablet, revealing an increasing drug load towards the tablets' outer boundaries and thus indicative of a radial displacement of drug particles during compaction. The presented method can be used for the quantitative analysis of drug content and drug distribution within pharmaceutical tablets, allowing for the optimization of fast disintegrating formulations. The results also affirm that that drug loads up to 20% will not lead to segregation for moxidectin.
More Related Videos
10:10Three-Dimensional Particle Shape Analysis Using X-ray Computed Tomography: Experimental Procedure and Analysis Algorithms for Metal Powders
Published on: December 4, 2020
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...