Related Experiment Video
Updated: Jan 3, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Are current wireless monitoring systems capable of detecting adverse events in high-risk surgical patients? A
Martine J M Breteler1, Eline KleinJan2, Lieke Numan3
1Department of Anesthesiology, University Medical Center Utrecht, Utrecht University, the Netherlands; Luscii Healthtech BV, Amsterdam, the Netherlands.
Background:
Adverse events are common in high-risk surgical patients, but early detection is difficult. Recent innovations have resulted in wireless and 'wearable' sensors, which may capture patient deterioration at an early stage, but little is known regarding their ability to timely detect events. The objective of this study is to describe the ability of currently available wireless sensors to detect adverse events in high-risk patients.
Methods:
A descriptive analysis was performed of all vital signs trend data obtained during an observational comparison study of wearable sensors for vital signs monitoring in high-risk surgical patients during the initial days of recovery at a surgical step-down unit (SDU) and subsequent traumatology or surgical oncology ward. Heart rate (HR), respiratory rate (RR) and oxygen saturation (SpO2) were continuously recorded. Vital sign trend patterns of patients that developed adverse events were described and compared to vital sign recordings of patients without occurrence of adverse events. Two wearable patch sensors were used (SensiumVitals and HealthPatch), a bed-based mattress sensor (EarlySense) and a patient-worn monitor (Masimo Radius-7).
Results:
Twenty adverse events occurred in 11 of the 31 patients included. Atrial fibrillation (AF) was most common (20%). The onset of AF was recognizable as a sudden increase in HR in all recordings, and all patients with new-onset AF after esophagectomy developed other postoperative complications. Patients who developed respiratory insufficiency showed an increase in RR and a decrease in SpO2, but an increase in HR was not always visible. In patients without adverse events, temporary periods of high HR and RR are observed as well, but these were transient and less frequent.
Conclusions:
Current systems for remote wireless patient monitoring on the ward are capable of detecting abnormalities in vital sign patterns in patients who develop adverse events. Remote patient monitoring may have potential to improve patient safety by generating early warnings for deterioration to nursing staff.
More Related Videos
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Aneurysm IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Peripheral Artery Disease V: Postoperative Nursing Management