Correcting the Error in Measuring Radiation Received by a Person: Introducing Cylindrical Radiometers
1Landscape Architecture and Urban Planning, Texas A&M University, College Station, TX 77843, USA.
Abstract:
Most human energy budget models consider a person to be approximately cylindrical in shape when estimating or measuring the amount of radiation that they receive in a given environment. Yet, the most commonly used instrument for measuring the amount of radiation received by a person is the globe thermometer. The spherical shape of this instrument was designed to be used indoors where radiation is received approximately equally from all directions. But in outdoor environments, radiation can be strongly directional, making the sphere an inappropriate shape. The international standard for measuring radiation received by a person, the Integral Radiation Measurement (IRM) method, yields a measure of the Mean Radiant Temperature (Tmrt). This method uses radiometers oriented in the four cardinal directions, plus up and down. However, this setup essentially estimates the amount of energy received by a square peg, not a cylinder. This paper identifies the errors introduced by both the sphere and the peg, and introduces a set of two new instrument that can be used to directly measure the amount of radiation received by a vertical cylinder in outdoor environments. The Cylindrical Pyranometer measures the amount of solar radiation received by a vertical cylinder, and the Cylindrical Pyrgeometer measures the amount of terrestrial radiation received. While the globe thermometer is still valid for use in indoor environments, these two new instruments should become the standard for measuring radiation received by people in outdoor environments.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Distance Corrections
Common Leveling Mistakes and Errors
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Uncertainty in Measurement: Reading Instruments
Adjusting a Traverse
Uncertainty in Measurement: Accuracy and Precision