Quantitative analysis of spectral Doppler clicks in assessment of aortic stenosis
Brent White1, Sean Wessel1, Weili Zheng1
1University of Illinois at Chicago, Chicago, IL, USA.
Objectives:
This study was performed to evaluate an additional echocardiographic spectral Doppler marker, which would identify severe aortic stenosis (AS).
Background:
Echocardiography is most commonly utilized to assess AS and has been validated against invasive measurements. However, the data obtained are not always in agreement, leaving a conundrum regarding the true severity of AS and can lead to other diagnostic procedures. This highlights the importance of improved noninvasive diagnostic techniques.
Methods:
Forty-eight indeterminate cases of calcific AS that had been previously evaluated by both echocardiography and cardiac catheterization were included in the study, using cardiac catheterization as the gold standard for calculation of aortic valve area (AVA). The intensity of opening and closing of the aortic valve, represented by bright vertical deflections on the CW spectral waveform, was quantified using ImageJ software to generate pixel intensity histograms to create opening and closing click (OC and CC) ratios. These ratios were compared with echocardiographic variables and catheterization AVA.
Results:
Thirty-five patients were found to have severe AS and 13 patients were found to have nonsevere AS, as assessed by cardiac catheterization. CC ratio was found to be a significant predictor of severe AS with an OR 0.024 (95% CI: 0.002-0.378, P = .0079). Adding CC to a model using standard echocardiographic parameters resulted in significant improvement in the C-statistic (0.693 to 0.835, P = .0134).
Conclusions:
An additional Doppler marker measuring the aortic valve CC ratio has been found to improve detection of severe AS.
More Related Videos
04:52A Modified Technique for Transverse Aortic Constriction in Mice
Published on: August 18, 2022
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops: