Related Experiment Video
Updated: Jan 3, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
The Screw-Aorta Dilemma: Changing Patient Position in Computed Tomography Scan Is Critical in Documenting Aortic
Vishal Sarwahi1,2, Jesse Galina1,2, Stephen Wendolowski1,2
1Department of Pediatric Orthopaedics, Cohen Children's Medical Center, Northwell Health System, New Hyde Park, NY.
Study Design:
Retrospective chart review.
Objective:
To determine if obtaining a prone computed tomography (CT)-scan can better delineate a questionable screw-aorta relationship.
Summary Of Background Data:
Pedicle screw misplacement rate is reported between 6% and 15%. Studies looking at misplacements on a per patient basis show up to 14% of patients have screws at risk (impinging vital structures). A screw abutting the aorta is a management challenge and often requires vascular surgery intervention. However, CT scans routinely done in supine position may overestimate screw-aorta relationship. Change in patient position may allow the aorta to roll away and, in most cases, reveal an uncompromised aorta. This will allow safe removal of pedicle screws without any vascular intervention.
Methods:
One hundred eleven spinal deformity patients who underwent Posterior spinal fusion from 2004 to 2009 were evaluated. Patients with concerning screw-aorta relationship underwent additional prone CT scan. Mobility of the aorta was determined and distance was compared using prone and supine CT scans.
Results:
Two thousand two hundred ninety five screws were reviewed, 36 screws in 18 patients were in proximity to the aorta. Fourteen screws (nine patients) appeared to be impinging the aorta. On prone CT, 13 out of the 14 instances the aorta moved away from the screw. The average distance at the screw level was 13.6 ± 4.8 mm in supine position and 8.9 ± 5.4 mm in prone position (P = 0.001). In one instance the relationship was unchanged on prone CT. No screw was noted to violate the lumen or distort the aorta.
Conclusion:
Supine CT scan alone is not entirely accurate in determining screw-aorta relationship. Prone-CT scan provides additional information for better delineation. This additional diagnostic step can change the treatment option by limiting the need for vascular intervention. When in doubt, the additional use of an arteriogram can allow for improved visualization.
Level Of Evidence:
3.
More Related Videos
07:12Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...