Simultaneous separation and determination of seven chelating agents using high-performance liquid chromatography
Zihe Liu1, Yuancai Chen1, Yongyou Hu1
1Ministry of Education Key Laboratory of Pollution Control and Ecological Remediation for Industrial Agglomeration Area, School of Environment and Energy, South China University of Technology, Guangzhou, P. R. China.
Abstract:
We describe an optimization approach to determine simultaneously occurring chelating agents (glycine, malonic acid, citric acid, glycolic acid, lactic acid, DL-malic acid, and ethylenediaminetetraacetic acid) in an electroplating effluent using high-performance liquid chromatography. With chromatography signal area and overall resolution considered as responses, detection conditions were optimized via multiple functions combined with response surface methodology and Plackett-Burman design. Optimized detection conditions were as follows: 15 mmol/L ammonium phosphate buffer (pH 2.5), a 94:6 v/v ratio of ammonium phosphate buffer/acetonitrile, a column temperature of 23.3°C, and a mobile phase flow rate of 1 mL/min. The experimental values conformed to the predicted values and were repeatable (relative standard deviation < 6.4%) and linear (r2 > 0.991) over concentration ranges of 1-100 µmol/L. Moreover, the quantification limit (signal-to-noise ratio = 10) and the detection limit (signal-to-noise ratio = 3) ranged from 0.03 to 0.15 µmol/L and from 0.01 to 0.04 µmol/L, respectively. These results indicate that high-performance liquid chromatography coupled with statistical design may be a simple and rapid method for simultaneously determining multiple chelating agents in electroplating wastewater effectively.
More Related Videos
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
